Miele DGC 5080 Convection Oven User Manual


 
Condensate tray
Place the condensate tray on the lowest shelf runner when
using perforated containers or roasting on the rack. The tray
will collect any drops of liquid and allow them to be removed
easily.
Grease filters
The grease filter in the oven ceiling must be fitted for every
programme.
Fit the grease filter in the back wall for all roasting
programmes.
It should be removed when using steam programmes.
It must be removed when baking, as otherwise results can be
uneven (Exception: fit the grease filter in the back wall when
baking open deep fresh fruit flans, e.g. plum or damson or
pizza with lots of topping).
Water container
The maximum water level is 1.2 litres, the minimum 0.75 litres.
The water level markers are located inside and outside the
container. On no account exceed the upper or maximum
level marker.
The maximum quantity of 1.2 litres of water is sufficient to run
a cooking programme at 100 °C for approx. 2 hours, and the
minimum quantity of 0.75 litres of water is sufficient to run a
cooking programme at 100 °C for approx. 30 minutes,
providing the door is not opened.
The water level in the water container is represented by a
symbol in the display.
Temperature / Core temperature
Some functions have recommended temperatures and where
appropriate a pre-set core temperature for the food probe.
You can alter the recommended temperature within a given
range (see "Functions") for an individual cooking process or
permanently (see "Settings"). You can alter the core
temperature for the food probe within a given range for an
individual cooking process or a cooking stage.
Description of the functions
17