All electrical work should be
undertaken by a suitably qualified
and competent person in strict
accordance with national and local
safety regulations.
Installation, repairs and other work
by unqualified persons could be
dangerous. The manufacturer
cannot be held responsible for
unauthorised work.
Ensure power is not supplied to the
appliance while installation or repair
work is being carried out.
The voltage, rated load and fusing are
given on the data plate, visible below
the oven interior, with the oven door
open. Ensure that these match the
household mains supply. Please quote
these data, and the model and serial
number when contacting the Miele Ser-
vice dept.
Connection of this appliance should be
made either via a suitable isolator,
which complies with national and local
safety regulations, and the on/off switch
should be easily accessible after the
appliance has been built in.
If the socket is not accessible after
installation (depending on country) an
additional means of disconnection must
be provided for all poles.
For extra safety it is advisable to install
a residual current device with a trip
current of 30 mA (in accordance with
DIN VDE 0664, VDE 0100 Section 739).
When switched off there must be an
all-pole contact gap of 3 mm in the
isolator switch (including switch, fuses
and relays acc. to EN 60 335).
Electrical connection UK, ZA