NEC 616 Yogurt Maker User Manual


 
On the CPU-S KTU is a momentary switch for system
reset. Depressing the reset switch causes any program
changes to enter the working program and interrupts
all system operation in progress.
2. CLK-S KTU
SW1
When DCI-S KTU(s) is installed ensure the switches
SW1 and SW2 on the CLK-S KTU are set to appro-
priate positions. Refer to Table 230-2 below. The
switch settings are subject to the dialing specifications
of the CO or PBX. The switches have been set by the
manufacturer at 1Opps dial speed and at 39% make
ratio.
Table 230-2
Rotary Dial Pulse Signalling Switch Settings
Dial Speed SW1
; :z; /
230.4
installing Optional KTUs
1. PBS-S KTU
Install PBS-S KTU in ES-6-1 KSU when External
Paging,Busy Lamp Field and/or Security options are
required. Refer to Section 250.2 “EB-6-1 Installa-
tion” for BLF connection. When installing External
Paging and/or Security options, see Section 260, Instal-
ling Options”.
7
__ DPH-S KTU
When a DPH-S KTU is installed in the ES-6-l KSU,
two DP-6-1 can be used as Door Phone or Monitor
Phone separately.
When Door Phone 1 is required as a Door Phone, set
the SW1 to the “D” position on the DPH-S KTU.
(In the case of Door Phone 2, set the SW3 to the
“D” position.)
When Door Phone 1 is required as a Monitor Phone,
set the SW1 to the “M” position on the DPH-S KTU.
(In the case of Door Phone 2, set the SW3 to the “M”
position.) and remove the straps Sl and S2 on the
DPH-S KTU. (In the case of Door Phone 2, remove
the straps S3 and S4). Then the voice from Key Set
will be cut off when Door Phone is accessed, and the
voice from DP-6-l is more amplified compared with
being used as Door Phone.
Page 200-4
D--M
Fig. 230-2
Door Phone/Monitor Phone
Select Switches
3. AHR-S KTU
Located on each DCI-S and MFI-S KTUs are three
straps (one for each line circuit) that should be
removed when AHR-S KTU is installed for Auto-
matic Hold Release option. When AHR-S KTU is not
installed, the straps should be left connected to the
solder terminals. Refer to Figure 230-3 for terminal
designations. The AHR-S will release a CO/PBX line
which is on hold when the outside party abandons the
call. A timed disconnect signal of more than 150 milli-
seconds must be provided from the CO or PBX to
enable this option (the AIIR-S does not recognize a
reversal of polarity). The AHR-S KTU serves up to
6 CO/PBX lines and is installed in ES-6-l KSU.
Remove the straps when AHR-S KTrJ is installed.
I
/
1
DCI-S 1
or
MFI-S 1
Line Circuit 3
Line Circuit 6
Fig. 230-3
DCI-S and MFI-S AHR Straps