Samsung RM255BASB Refrigerator User Manual


 
OPERATING INSTRUCTIONS & INSTALLATION
No ITEM
I/M-SENSOR
R-SENSOR
R-FAN ERROR
-
CR SENSOR
EXT-SENSOR
F-SENSOR
TROUBLE
REMARK
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
DEFROSTING
SENSOR OF R
COMPARTMENT
DEFROSTING
SENSOR OF CR
COMPARTMENT
DEFROSTING
SENSOR OF CF
COMPARTMENT
CR-DEFROST
ERROR
CF-DEFROST
ERROR
WATER
HEATER ERROR
I/M FUNCTION
ERROR
R-DEFROSTING
ERROR
Electric wire cut, short-circuit, contact failure, sensor housing missing, while in
case of displaying a temperature defect, it is only displayed when the sensor
detected temperature is not lower than 122
nor higher than -58
Electric wire cut, short-circuit, contact failure, sensor housing missing, while in
case of displaying a temperature defect, it is only displayed when the sensor
detected temperature is not lower than 122
nor higher than -58
Electric wire cut, short-circuit, contact failure, sensor housing missing, while in
case of displaying a temperature defect, it is only displayed when the sensor
detected temperature is not lower than 122
nor higher than -58
AN error is displayed when there is a contact failure on the feedback signal
line, a motor wire missing or a defect of the motor itself, when operating the
relevant fan motor.
An error is displayed when there is bad horizontality and bad ice tray more
than twice for each item of the ice maker kit.
** Pertinent only to dispenser models (external attachment type).
Error occurs and is displayed when regarding the R compartment defrosting heater, there is an electric wire
cut, short-circuit, contact failure, sensor housing missing, or defective temperature fuse. A defect is
displayed if defrosting is not finished after continuous heating for more than 70 min, for the R compartment.
Electric wire cut, short-circuit, contact failure, sensor housing missing, while in case
of displaying a temperature defect, it is only displayed when sensor detection
temperature is not lower than 122 nor higher than -58
Electric wire cut, short-circuit, contact failure, sensor housing missing, while in case
of displaying a temperature defect, it is only displayed when sensor detection
temperature is not lower than 122 nor higher than -58
Electric wire cut, short-circuit, contact failure, missing of sensor housing , while in
case of display of defect by temperature, it is only displayed when sensor detection
temperature is not lower than 122 or not higher than -58
Error occurs and is displayed when regarding the CR compartment defrosting heater, there is an electric wire
cut, short-circuit, contact failure, sensor housing missing, or defective temperature fuse. A defect is displayed
if defrosting is not finished after continuous heating for more than 70 min, for the CR compartment.
Error occurs and is displayed when regarding the CF compartment defrosting heater, there is an electric wire
cut, short-circuit, contact failure, sensor housing missing, or defective temperature fuse. A defect is displayed
if defrosting is not finished after continuous heating for more than 70 min, for the CF compartment.
An Error is displayed in case of water heater housing missing or
electric wire cut.
Electric wire cut, short-circuit, contact failure, sensor housing missing, while in case
of displaying a temperature defect, it is only displayed when sensor detection
temperature is not lower than 122 nor higher than -58
Electric wire cut, short-circuit, contact failure, sensor housing missing, while in case
of displaying a temperature defect, it is only displayed when sensor detection
temperature is not lower than 122 nor higher than -58
󳀌 Error items of self-diagnostics