3-16) Load Condition Display Function
1) If the freezing setting + the refrigeration setting keys are pressed simultaneously for about 6 seconds under normal
operation condition, the freezer compartment and the refrigerator compartment temperature setting displays go on
ALL ON/OFF for about 2 seconds with a 0.5 second interval.
2) I the freezing setting + the refrigeration setting keys are pressed simulyaneously then released, and the Fresh Zone
setting key is pressed (to generate a ding-dong sound), the load status display mode is introduced.
3) Load status display mode tells what kind of load is output by the current MICOM signal. I tells only that a MICOM
signal has been output but it does not confirm whether or not the load actually oper
ates. So even if the display output
shows that the load is operating , in reality the load might not operate due to load abnormality, bad relay on PCB etc.
while as such this function may be used in A/S by application.
4) Load status display function is maintained for only 30 seconds after which it automatically returns to normal condition.
5) Relevant displays about load status is as follows.
󳀌 LOAD MODE CHECKLIST
No LOAD ITEM LOAD STATUS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
-
R-FAN HIGH
R-FAN LOW
R-DEF-HEATER
START MODE
OVERLOAD MODE
LOW TEMP. MODE
DISPLAY MODE
COMP
F-FAN HIGH
F-FAN LOW
F-DEF-HEATER
C-FAN HIGH
C-FAN LOW
DISPENSER-HEATER
R-VALVE
CR-FAN
CR-DEF-HEATER
ICE-PIPE-HEATER
F-VALVE
CF-FAN
CF-DEF-HEATER
WATER-HEATER
ORDINARY CONDITION
R-FAN High speed rotation operation display
R-FAN Low speed rotation operation display of R-FAN
Displays operation of the R compartment defrosting heater
Operation stage display (not important)
When ambient temperature is not higher than 93.2
When ambient temperature is not lower than 62.6
During display mode operation
COMP. operation display
F-FAN high speed rotation operation display
F-FAN low speed rotation operation display
Displays operation of the F compartment defrosting heate
C-FAN High speed rotation operation display
C-FAN low speed rotation operation display
Dispenser heater operation display
Is it lighted when the R-VALVE is OPEN
CR-FAN operation display
Operation display of CR compartment defrosting heater
ICE-PIPE heater operation display
IIs it lighted when the F-VALVE is OPEN
CF-FAN operation display
Displays operation of the CF compartment defrosting heater
Water heater operation display
When both no. 5 and 6 are lights-out (64.4
~93.2
)
FREEZER FRIDGE