Taylor C708 Freezer User Manual


 
16
Models C708 & C716Important: To the Operator
050628
Power Switch ON
When the power switch is plac ed in the ON position,
the control panel touch keys become operative. The
fluorescent display will be either blank or indicate
that the unit has been cleaned.
UNIT CLEANED
International Mod els Only:
Some International models will continuously display
the temperature of the mix hopper when the power
switch is in the ON position.
HOPPER 21.0
UNIT CLEANED
If the control is set for i nternational configuration, the
following screen will appear when the heat symbol is
touched.
ARE YOU SURE
>Yes
No
Use the up or down arrow symbol to move the
cursor to “YES”. Touch the SEL symbol to
immediately start a heat cycle.
Note: The machine must be in AUTO or STANDBY
and have s ufficient mix in the hopper before the
machine can successfully enter the HEAT mode of
operation.
Heat Cycle
The HEAT symbol on the control panel is illuminated
throughout the heat treatment cycle. Two warning
messages will be displayed on the screen. “DO NOT
DRAW” will be dis played when the mix temperature
is below 130° F (54.4°C).
DO NOT DRAW
When the temperature of the mix i s above 130°F
(54.4°C) the screen will dis play a message
indicating that HOT PRODUCT is in the machine.
HOT PRODUCT
DO NOT attempt to draw product or
disassemble the unit during the HEAT cycle. The
product is hot and under extreme pressure.
In the HEAT cycle, the mix temperature in the
hopper and freezing cylinder must be raised to
151°F (66.1°C) within 90 minutes.
When the heating phase is complete, the freezer
goes into the holding phase of the cycle. The holding
phase will k eep the temperature above 151°F
(66.1°C) for a minimum o f 3 5 minutes.
The final phase of the heat treatment cycle i s the
cooling phase. The freezer must cool the mix below
41°F (5°C) within 90 minutes.
When the entire heat cycle has been completed, the
HEAT symbol will no longer be illum inated. The
machine will enter the S TANDBY mode (STANDBY
symbol illuminates). The machine c an be placed in
AUTO or left in STANDBY.
To comply with health codes, heat treatment system
freezers must complete a heat treatment cycle
daily, and must be disassembled and brush cleaned
a minimum of every 1 4 days. Brush cleaning is the
normal disassembly and cleaning procedure found in
the Operator Manual. Failure to follow these
guidelines will c ause the control to lock the freezer
out of the AUTO mode.