11. Poor ice quality (soft or unclear cubes)
Cause
a. Poor incoming water quality.
b. Deposit build-up on evaporator grid.
c. Water splashing on cubes.
12. Unit not freezing (compressor and fan
operating)
Cause
a. Little or no cooling.
b. Bypass valve stuck in open position.
13. Unit produces shallow or incomplete cubes or
the ice fill pattern on the grid is incomplete
Cause
a. Low water level.
b. Low water pressure.
c. Unit is not level.
d. Operating unit without back or front panel.
e. Bad thermistor.
f. Bad control board.
14. Not freezing compressor not running / fan
operating
Cause
a. Bad overload (open).
b. Bad compressor.
15. Not freezing (compressor and fan not
operating)
Cause
a. No electrical power to unit.
b. Rocker switch defective or wired incorrectly.
Remedy
a. Consult a plumber.
b. Run the unit through a clean cycle. Use only
U-Line Ice Machine Cleaner.
c. Adjust water flow above evaporator.
Remedy
a. Check sealed system for leak or restriction.
NOTE: See chart of suction pressures in manual.
b. Replace bypass valve.
Remedy
a. Check that standpipe is fully seated inside
water trough.
b. Check water pressure into water valve
(pressure should be 20 to 120 psi).
c. Level unit to assure even water flow. Uneven
water flow will reduce ice rate and cause
incomplete cubes. See Leveling Instructions in
manual.
d. Install back or front panel. The unit will harvest
ice according to temperatures of tubing at
condensing coil. Increased air flow will give
the thermister false information. This info could
cause the ice to eject prematurely.
e. Replace thermister.
f. Replace control board.
Remedy
a. Replace overload.
b. Replace compressor.
Remedy
a. Make sure unit is plugged in and outlet has
power.
b. Make sure switch is wired correctly and set in
“ICE” position.