90
Design
■
Features
■
Performance
LEVELING AND INSTALLATION REQUIREMENTS
It is extremely important that the unit is level. If it is not
level, the ice mold will not fill evenly. This can cause a
reduction in ice rate, uneven sized cubes or water spilling
into the storage area which will cause the ice in the bin to
melt prematurely. See Figure A.
Remember the floor surrounding a drain has a tendency to
slope towards the drain.
Leveling the Unit
1. Use a level to check the icemaker from front to back and
from side to side. See Figure B.
2. If the icemaker is not level, adjust the feet on the corners
of the unit as necessary. See Figure C.
3. Check after each
adjustment and
repeat the
previous steps
as necessary
until the unit
is level.
Installation Requirements
• The unit may be built into a cabinet. There is no minimum clearance requirement for the top, left or
right sides of the unit.
• The location must allow enough clearance for water, drain, and electrical connections in the rear of
the unit.
• The location must not obstruct air flow to the front of the unit.
CLR2060 MODEL
UL307
UL314
CHECK
LEVEL
UL205A
TURN FOOT TO ADJUST
Figure A
Figure B
Figure C