Wiring Diagram (Figure 41)
Figure 41
1. Connect (1) wire from the 750 millivolt wall thermostat and (1)
wire from appropriate accessory to the GREEN, stripped and
bare wire from the ON/OFF/REMOTE wire harness.
2. Connect (1) wire from the 750 millivolt wall thermostat and (1)
wire from appropriate accessory to the RED, stripped and bare
wire from the ON/OFF/REMOTE wire harness.
Note: When the appliance is in the MANUAL mode and the
batteries fail in the FRBC-1 or if the electric (120 volt) fails in
the FREC-1, and immediate heat is desired, turn the ON/OFF/
REMOTE switch on wire channel from the REMOTE position
to the ON position.
Manual Operation
1. Turn ON/OFF/REMOTE switch on wire channel to REMOTE
position.
2. Turn wall thermostat OFF.
3. Turn accessory, FRBC-1, FREC-1 or FWS-1, ON. Appliance
is now in the manual mode. You must turn the appliance ON or
OFF with appropriate accessory.
Wall Thermostat Operation
1. Turn the ON/OFF/REMOTE switch on wire channel to REMOTE
position.
2. Turn accessory, FRBC-1, FREC-1 or FWS-1, OFF.
3. Turn wall thermostat ON and set appropriate temperature. Wall
thermostat will cycle the appliance ON and OFF.
Installation of Remote Receiver (Figure 40)
1. Attach, from left to right, the slide-on cover plate onto the remote
receiver.
ON will be to the top and OFF will be to the bottom
on the slide-on cover plate.
2. Push the receiver slide button onto the receiver slide switch.
Reverse installation of the slide button if it is off center.
3. Attach velcro loop on the left side of the valve cover support.
4. Attach velcro hook onto remote receiver. The word TOP on the
remote receiver should be to the top when installed onto valve
cover support.
5. Attach velcro hook on remote receiver onto velcro loop on valve
cover support.
Refer to remote control installation and operating instructions for
more details on remote control.
Figure 40
WIRING (continued)