This model is a direct vent gas appliance and is designed to operate with
all combustion air being siphoned from the outside of the building and
all exhaust gases expelled to the outside of the building.
Warning: This unit is not for use with solid fuel.
Pre-Installation Preparation
This direct vent gas fireplace and its components are tested and safe when
installed in accordance with this Installation Manual. Report to your
dealer any parts damaged in shipment, specifically check glass condition.
Do not install unit with damaged, incomplete, or substitute parts. Read
all instructions before starting installation and follow these instructions
carefully during installation to insure maximum benefit and safety. Failure
to follow them will void your warranty and may present a fire hazard.
The Empire Comfort System, Inc. warranty will be voided by, and Empire
Comfort System, Inc. disclaims any responsibility for the following
actions:
Installation of any damaged fireplace or vent system component.
Modification of the fireplace or direct vent system.
Installation other than as instructed by Empire Comfort System, Inc.
Improper positioning of the gas logs or the glass door.
Installation and/or use of any component part not manufactured or
approved by Empire Comfort System, Inc.
High Altitude Installation
When installing this unit at an elevation above 2000 feet (in the United
States) it may be necessary to decrease the input rating by changing
the existing burner orifice to a smaller size. Generally, input should be
reduced 4 percent for each 1000 feet above sea level. However, if the
heating value of the gas has been reduced, this general rule may not
apply. Check with local gas utility for proper orifice size identification.
APPLIES TO CANADIAN MODELS ONLY
Altitude: 0-4,500 feet (0-1370 m) without orifice change.
For high altitude installations consult the local gas distributor or the authority
having jurisdiction for proper rating methods. If the installer must convert
the unit to adjust for varying altitudes, the information sticker (illustrated
below) must be filled out by the installer and adhered to the appliance at
the time of conversion.
THE CONVERSION SHALL BE CARRIED OUT BY A MANUFACTUR
-
ER'S AUTHORIZED REPRESENTATIVE IN ACCORDANCE WITH
THE REQUIREMENTS OF THE MANUFACTURER, PROVINCIAL
OR TERRITORIAL AUTHORITIES HAVING JURISDICTION AND IN
ACCORDANCE WITH THE REQUIREMENTS OF THE CAN/CGA-
B141.1 OR CAN/CGA-B141.2 INSTALLATION CODES.
LA CONVERSION DOIT ÊTRE EFFECTUÉE CONFORMÉMENT AUX
RÉGLEMENTATION PROVINCIAUX EN CAUSE ET AUX EXIGEN
-
CES DES CODES D'INSTALLATION CAN/CGA-B149.
This appliance has been converted for use at an altitude of
Orifice size
Manifold Pressure
Input (Btu/h) Fuel Type
Date of Conversion Converted by
Cet appareil a été converti au
Injecteur
Pression à la tubulure d'alimentation
Déoit calorifique
Instructions to Installer
1. Installer must leave instruction manual with owner after
installation.
2. Installer must have owner fill out and mail warranty card supplied
with appliance.
3. Installer should show owner how to start and operate appliance and
thermostat.
This appliance is design certified in accordance with American National
Standard/CSA Standard ANSI Z21.88/CSA 2.33 by the Canadian Standards
Association as a Direct Vent Fireplace and should be installed according
to these instructions.
The efficiency rating of this appliance is a product thermal efficiency rating
determined under continuous operating conditions and was determined
independently of any installed system.
Any alteration of the original design, installed other than as shown in
these instructions or use with a type of gas not shown on the rating plate
is the responsibility of the person and company making the change.
Notice:
:
During initial firing of this unit, its paint will bake out and smoke
will occur. To prevent triggering of smoke alarms, ventilate the room in
which the unit is installed.
Appliance must not be connected to a chimney flue that is servicing a
separate solid-fuel burning appliance.
Attention: All vent runs must have a minimum VERTICAL rise of two
feet. If the vent run is directly behind the appliance, you must attach
36" snorkel Simpson Dura-Vent SD-981 or Selkirk 4DT-ST36 on the
exterior of the building. See Venting Fireplace, page 16.
Installation in Residential Garages
Gas utilization equipment in residential garages shall be installed so
that all burners and burner ignition devices are located not less than 18"
(457mm) above the floor.
Such equipment shall be located, or protected, so it is not subject to physical
damage by a moving vehicle.
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment or
accessories and repair and servicing of equipment shall be performed
only by a qualified agency. The term "qualified agency" means any
individual, firm, corporation or company which either in person or through
a representative is engaged in and is responsible for (a) the installation
or replacement of gas piping or (b) the connection, installation, repair or
servicing of equipment, who is experienced in such work, familiar with
all precautions required and has complied with all the requirements of the
authority having jurisdiction.
State of Massachusetts: The installation must be made by a licensed
plumber or gas fitter in the Commonwealth of Massachusetts.
The installation must conform with local codes, or, in the absence of local
codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA54* Canadian
Installation Code, CAN/CGA B149.
*Available from the American National Standards Institute, Inc., 11 West
42nd St., New York, NY 10036.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence
de tels règlements, selon les Codes d'installation CAN/CGA-B149.
INTRODUCTION