WMF Americas 1400 Coffeemaker User Manual


 
Appendix: Technical Data
59
User Manual WMF presto
Mains voltage tolerance 230 V + 6 % - 10 %, mains outage < 50 ms no
interruption of function
Water supply
(optional constant water
connection)
3/8 inch flexihose connector with mains tap and
filter on customer supply side, water temperature
max. 35 °C.
min. 2 bar flow pressure ati 2 l/min., max. 6 bar
Water quality For drinking water over 5° dCH (carbonate hard-
ness) a WMF anti-scale filter should be included.
Drain outlet
(optional)
Flexihose to DN 19, min. gradient 2 cm/m
Ambient temperature + 5°C to max. + 35°C
(Do not expose the coffee machine to frost).
Maximum humidity
Protection
80 % relative humidity without condensation,
no water spray, do not use unit outdoors!
IP X0
Inbuilt clearances For operating, service and safety reasons the
machine should be installed with clearance of not
less than 50 mm at the back and sides from the
building or non-WMF components.
A clear height of 100 mm from the top of the sup-
porting surface should be ensured. Recommen-
ded height of the working surface is a minimum of
850 mm from floor level.
If the machine connections are to be routed down
through the counter, remember also to allow
space for the connections. These may restrict the
available space below the machine.
Anti-scale filter installed
dimensions (03.9314.0001)
490 mm (height) x 118,8 mm (diameter)
plus space requirement for the connection tubes
* The existing electricity supply must conform to the currently valid national rules (for Germany, VDE 0100).
To improve safety the coffee machine should be fitted with an FI 30 mA earth leakage current circuit breaker
to EN 61008 standards. A plug top wall socket should be fitted near the machine. If the mains connection
lead of this coffee machine is damaged it must be replaced by WMF Customer Services or a similarly qualified
person.
If the coffee machine is permanently connected to the mains then an all-pole disconnecting separator (mains
switch) to EN 60947 standards with a minimum 3 mm contact gap must be included. For flexible connection a
separator switch is recommended.
Mains cable must not come into contact with hot surfaces.
Mains switch and plug top are part of the customer‘s on-site installation.
The machine may not have a fixed permanent mains connection if installed on any mobile furniture item.