8
When two or more modules are installed
together, an integrated module filler strip
(
IFILLER/S) is recommended. Contact your
Wolf dealer for information on accessories.
IMPORTANT NOTE:
Review specific
installation instructions for product to product
c
apabilities.
WOLF FRYER MODULE
MANUAL DRAIN OUTLET
IMPORTANT NOTE:
The fryer module must be
installed in a base cabinet that allows access to
t
he manual drain valve for draining the oil. A
heat-resistant bucket must be positioned under
the drain outlet to accept the oil. The bucket
m
ust be able to hold 7.6 L. Refer to the Instal-
lation Specifications illustration on
page 7 for location of the manual drain outlet.
MULTIPLE COOKTOP INSTALLATION
IMPORTANT NOTE:
If the fryer module is to
be used with a combination of additional
cooktop units or modules with a filler strip,
the cut-out width is calculated by adding the
corresponding units' cut-out dimensions plus
32 mm for each additional unit.
When multiple units are installed side by side,
each unit must have its own separate recom-
mended electrical circuit.
64
mm
min
FRONT OF COUNTERTOP
489
mm
CUT-OUT
DEPTH
743
mm
TWO MODULES WIDTH
1130
mm THREE MODULES WIDTH OR
1124
mm / 762 mm COOKTOP AND ONE MODULE
1518
mm FOUR MODULES WIDTH OR
1511
mm / 762 mm COOKTOP AND TWO MODULES OR
1276
mm / 914 mm COOKTOP AND ONE MODULE
356
mm
CUT-OUT
WIDTH
Countertop cut-out dimensions for installation of multiple cooktops
This fryer module must be installed at
least 381 mm away from any open-flame
cooking device. The open flame may
cause ignition of oil.
This fryer module must be installed at
least 381 mm away from a W
olf steamer
module, as contact between water and
hot oil may cause burns from steam and
hot oil.