J1 connector, rear panel view
Fig.6-2: Remote resistive programming
RESISITIVE PROGRAMMING OF OUTPUT VOLTAGE AND CURRENT LIMIT
For resistive programming, internal current sources, for Output Voltage and/or Output Current control,
ply 1mA current through external programming resistors connected between J1
& 23. The voltage across the programming resistors is used as a programming voltage for the power
10Kohm can be selected to program the
urrent from zero to full scale.
control the output over its entire range, or a combination of variable r
tors can control the output over restricted portion of its range.
Perform the following procedure to set the power supply to Resistive programming:
urn the AC On/Off switch to Off.
1 to its UP position for output voltage external programming and SW1
its UP position for Output Current limit external programming.
Set SW1, position 3 to select the programming resistor range acco
7 to its UP position for output voltage resistive programming and SW1
tion for Output Current limit resistive programming.
Connect a short between J1
ing resistors to the mating plug of J1 as shown in Fig.6
Set the programming resistors to the desired resistance and turn the power supply ON. Adjust the
resistors to change the power supply output.
SW1, positions 4, 5, 6 and 9 are not required
for remote programming. Their settings can be d
termined according to the application requirements.
The control circuits allow the user to set the Output Voltage and Output Current up to 5% over the
rated maximum value. The power supply will operate
within the extended range, ho
is not recommended to operate the power supply over its voltage and current rating and perfor
To maintain the temperature stability specification of the power supply, the resistors used for pr
ramming should be stable and low noise resistors, with temperature coefficient of less than
When resistive programming is used, front panel and computer control (via serial communication
port) of Output Voltage and Current are disabled.
Output Current programming
3 setting and programming range