Chapter 6 Fault Codes and Descriptions |DD Series
6-6
Display Description Corrective Actions
Door width auto-tuning error
Check the wiring of the encoder
Open door time-out
Check if door opens fluently.
6.1.1 Reset
There are three methods to reset the AC motor drive after the fault is corrected:
1. Press
RESET
STOP
key on KPV-CE01.
2. Set external terminal to “RESET” and then set the contact ON.
3. Send “RESET” command by communication.
NOTE
Make sure that RUN command or signal is OFF before executing RESET to prevent damage or
personal injury due to immediate operation.