Chapter 4 Parameter Settings|DD Series
4-55
Larger current is required at the beginning of door open and door close, so it needs to have larger
re-open current level in the acceleration area. Please refer to the following figure for setting reopen
current and acceleration area:
Door Close
Holding Speed
Open Door (REV
)
Close Door (FWD)
04.00
Door Open
Speed
by Initial
04.08
Door Open
Acceleration
Time 1
04.09
Door Open
Deceleration
Time 1
04.03
Door Open High Speed 1
04.05
Door Open
Final Speed
04.01
Door Open Distance by
Initial Speed
04.04
Door Open
by Final Speed
Begi ns
04.06
Door Open
by Holding Speed
Begi ns
04.07
Door Open
Holding Speed
05.03
Door Close
High Speed 1
05.08
Door Close
Accelerati on Time 1
05.05
05.04
05.06
Door Close
byHolding
Speed
Begins
05.07
05.09
05.01
Door Close
Distance by
Initial Speed
05.00
Door Close
Initial Speed
Door Close
Final Speed
Door Close
Final Speed
Door Close
by Final Speed
Begi ns
Door Open Limit
100.0%
Re-open Detected Area
Door Close Limit
0.0%
05.25
Door reopen current level 1
05.25 * 04.11/100
Door Re-open Current Level
for Acceleration Area
05.32
Door Re-open
Acceleration
Boundary
05.31
Door Re-open
Low Speed Boundary
Door Close Error Deceleration Time
Control mode VF VFPG SVC FOCPG FOCPM
Factory setting: 0.4
Settings 0.1~3600sec
Door Re-open Detection Time
Control mode VF VFPG SVC FOCPG FOCPM
Factory setting: 0.2
Settings 0~10.0sec