3Com VFD-D D Refrigerator User Manual


 
Chapter 4 Parameter Settings|DD Series
4-44
03 Feedback Parameter This parameter can be set during operation.
Encoder (PG) Signal Type
Control mode
VFPG
FOCPG FOCPM
Factory setting: 7
Settings
0: No function
1: ABZ
7: PWM pulse
Detection of the magnetic pole: Setting 1: The AC motor drive will output short circuit to detect the
position of the magnetic pole. At this moment, the motor will generate a little noise.
Reference table for encoder and tuning
Setting of PG signal type Encoder (PG) Signal type Pr.01-00=01 Pr.01-00=03
03.00=1 A, B, Z Motor will run Motor will run
03.00=7 PWM Motor will run Motor will run
Encoder pulse
Control mode
VFPG
FOCPG FOCPM
Factory setting: 256
Settings 1~25000
A Pulse Generator (PG) or encoder is used as a sensor that provides a feedback signal of the motor
speed. This parameter defines the number of pulses for each cycle of the PG control (PPR).
Encoder Input Type Setting
Control mode
VFPG
FOCPG FOCPM
Factory setting: 1
Settings 0: Disable
1: Phase A leads in a forward run command and phase B leads in a reverse run
command
Forward
running
A
B
FWD
REV
2: Phase B leads in a forward run command and phase A leads in a reverse run
command
Forward
running
A
B
FWD
REV
3: Phase A is a pulse input and phase B is a direction input. (low input=reverse
direction, high input=forward direction)
Forward
running
A
B
FWD
REV
4: Phase A is a pulse input and phase B is a direction input. (low input=forward
direction, high input=reverse direction)
Forward
running
A
B
FWD
REV
5: Single-phase input
Forward
running
A
It is helpful for the stable control by inputting correct pulse type.