3Com VFD-D D Refrigerator User Manual


 
Chapter 4 Parameter Settings|DD Series
4-41
Multi-function Output (MO3)
Factory setting: 0
Settings Control mode
VF VFPG SVC FOCPG FOCPM
0: No function
1: AC drive in operation
2: Zero speed frequency signal (including STOP)
3: AC drive ready
4: Low voltage warning(Lv)
5: Fault indication
6: Overhead warning (Pr.06.09)
7: Detection of braking resistor action level
8: Warning indication
9: Over voltage warning
10: OD command
11: CD command
12: Demo Indication
13: Demo complete
14: Emergency stop indication
15: Force stop indication
16: Door open complete (limit) signal output
17: Door close complete (limit) signal output
18: Door Close Error
19: Position Complete Signal
20: Position Detection 1(for door close only)
21: Position Detection 2(for door close only)
22: Position Detection 3(for door close only))
23: Position Detection 1(for door open only)
24: Position Detection 2(for door open only)
25: Position Detection 3(for door open only)
26: PG feedback error
27: output signal when unable to open the door
28: over torque (OT1)
These parameters can be used for external terminal output
Summary of Function Settings
Settings Functions Descriptions
0
No function MO has no function.
01
AC drive in operation The drive is ON when it receives voltage or operation command.
2
Zero speed frequency signal
(including STOP)
Zero speed output signals (including STOP).
3
AC drive ready
Active when the drive is ON and no abnormality detected or
abnormality is cleared.
4
Low voltage warning(Lv) Active when the detected input voltage is too low.
5
Fault indication Active when fault occurs.
6
Overhead warning (Pr.06.09)
A
ctive when IGBT or heat sink overheats to prevent OH turn off
the drive. When temperature higher than 85 = ON, lower than
<80 = OFF .
7
Detection of braking resistor
action level
Active when drive begins software braking, this signal can be
used as brake module VFDB action signal or indicator.
8
Warning indication Active when warning is detected.
9