3Com VFD-D D Refrigerator User Manual


 
Chapter 4 Parameter Settings|DD Series
4-25
5: Display output power (kW)
6: Display motor angle speed (HU)
7: Display the drive’s estimated output torque (kg-m)
8: Display PG pulse input position
9: Display the electrical angle
10: Display IGBT temperature(oC)
11: Display digital input ON/OFF status
12: Display digital output ON/OFF status
13: Display current multi-step speed
14: Display the corresponding CPU pin status of digital input
15: Display the corresponding CPU pin status of digital input
16:Actual output voltage when malfunction
17: Actual DC-BUS voltage when malfunction
18: Actual output frequency when malfunction
19: Actual output current when malfunction
20: Actual frequency command when malfunction
21: Door width in % or step speed
22: Door width(pulse)
23: Over modulation indication
Description to function 08
rpm
60
XPPR)/1000]X10=
Pulse/10ms
[(
rpm=motor speed; PPR= (Encoder) pulse number per turn; 1000 (1sec= 1000ms); 10: encoder pulses
per10ms
On this page, press
to display the content of Pr.00.04 (setting 0~23) accordingly.
Software version
Control mode VF VFPG SVC FOCPG FOCPM
Factory setting: #. ##
Settings Read only (Different versions will display differently)
Password Input
Control mode
VF VFPG SVC FOCPG FOCPM
Factory setting: 0
Settings 0~9999
0~2:times of wrong password
Password Set
Control mode
VF VFPG SVC FOCPG FOCPM
Factory setting: 0
Settings
0~9999
0: No password set or successful input in Pr.00-06
1: Password has been set
The function of this parameter is to input the password that is set in Pr.0-07. Input the correct password
here to enable changing parameters. You are limited to a maximum of 3 attempts. After 3 consecutive
failed attempts, a blinking “PcdE” will show up to force the user to restart the AC motor drive in order to
try again to input the correct password.
To set a password to protect your parameter settings.
If the display shows 00, no password is set or password has been correctly entered in Pr.0-06. All
parameters can then be changed, including Pr.0-07.
The first time you can set a password directly. After successful setting of password the display will show
01.
Be sure to record the password for later use.
To cancel the parameter lock, set the parameter to 00 after inputting correct password into Pr. 0-07.