Chapter 4 Parameter Settings|DD Series
4-18
07 Control Parameters This parameter can be set during operation.
Paramete
r
Explanation Settings
Factory
Setting
VF
VFP
SVC
FOC
FOC
07.00
ASR (Auto Speed
Regulation) Control (P) of
Zero Speed
0.0~500.0% 1.5 ○ ○ ○ ○ ○
07.01
ASR (Auto Speed
Regulation) Control (I) of
Zero Speed
0.000~10.000sec 0.050 ○ ○ ○ ○ ○
07.02
ASR (Auto Speed
Regulation) Control (P) 1
0.0~500.0% 1.5 ○ ○ ○ ○ ○
07.03
ASR (Auto Speed
Regulation) Control (I) 1
0.000~10.000sec 0.050 ○ ○ ○ ○ ○
07.04
ASR (Auto Speed
Regulation) Control (P) 2
0.0~500.0% 3.0 ○ ○ ○ ○ ○
07.05
ASR (Auto Speed
Regulation) Control (I) 2
0.000~10.000sec 0.100 ○ ○ ○ ○ ○
07.06
ASR 1/ASR2 Switch
Frequency
0.00~120.00Hz (0:Disable) 2.00 ○ ○ ○ ○ ○
07.07
ASR Primary Low Pass
Filter Gain
0.000~0.350sec 0.008 ○ ○ ○ ○ ○
07.08
Zero Speed/ASR1 Width
Adjustment
0.00~120.00Hz 2.00 ○ ○ ○
07.09
ASR1/ASR2 Width
Adjustment
0.00~120.00Hz 5.00 ○ ○ ○
07.10
Mechanical Gear Ratio
1~100 1 ○ ○
07.11
Inertia Ratio
1~300% 100 ○ ○
07.12
Zero-speed Bandwidth
0~40Hz 20 ○ ○
07.13
Low-speed Bandwidth
0~40Hz 20 ○ ○
07.14
High-speed Bandwidth
0~40Hz 20 ○ ○
07.15
PDFF Gain Value
0~200% 0 ○ ○
07.16
Gain for Speed Feed
Forward
0~500 0 ○ ○