I N S T A L L A T I O N
An electrical wiring diagram is located in the front access
door of the fryer. The fryer must be installed by a
qualified electrician. This appliance must be branch circuit
protected with proper ampacities, in accordance with the
wiring diagram located in the fryer. The fryer must be
properly grounded in accordance with the National
Electrical Code and applicable local codes. A means to
disconnect the unit must be incorporated into the fixed
wiring in accordance with wiring codes.
Wire size for the main incoming power to the unit must
match the minimum size listed in the specifications
applicable to the specific fryer. For supply connections,
locate the wire size posted on the label located on the
electrical control box cover, behind the service panel or
elsewhere listed in this manual.
Before operating the fryer, check all cable connections in
the electrical connection area for tightness since
c
onnections can loosen during transport.
230V:
To prevent an electrical shock hazard between the
appliance and other appliances or metal parts in close
vicinity, an equalization-bonding stud is provided. An
equalization bonding lead must be connected to this
stud and the other appliances / metal parts to provide
sufficient protection against potential difference. The
terminal is marked with the following symbol.
ELECTRICAL - ASF-60E
VOLTAGE PHASE CYCLE/HZ AMPS kW
208-220
(AGCY) 3 60 47 17.93
at 208 3 60 45 16.2
at 220 3 60 47.6 18.2
240 (AGCY) 3 60 43 17.93
380-415
at 380 3 50 20.4 15.4
at 415 3 50 25.4 18.3
440-480
(AGCY) 3 60 21.8 18.1
at 440 3 60 20.4 15.5
at 480 3 60 22.2 18.5
No cord or plug
D A N G E R
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in according with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.
D A N G E R
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
E L E C T R I C A L R E Q U I R E M E N T S
ELECTRICAL - ASF-75E
VOLTAGE PHASE CYCLE/HZ AMPS kW AWG
208-220(AGCY) 3 60 68.2 26.0 AWG 2
at 208 3 60 66.6 24.0 AWG 2
at 220 3 60 70.8 27.0 AWG 2
240 (AGCY) 3 60 66.8 27.8 AWG 2
380-415
(AGCY) 3 50 38.1 27.5 AWG 6
at 380 3 50 35.2 23.2 AWG 6
at 415 3 50 38.2 27.5 AWG 6
440-480
(AGCY) 3 60 31.3 26.0 AWG 8
at 440 3 60 30.7 23.5 AWG 8
at 480 3 60 33.4 27.85 AWG 8
No cord or plug
D A N G E R
APPLIANCES WITH NO CORD
PROVIDED BY FACTORY MUST BE
EQUIPPED WITH A CORD OF
SUFFICIENT LENGTH TO PERMIT
THE APPLIANCE TO BE MOVED
FOR CLEANING.
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.