Broil King 9025 Oven User Manual


 
12
C.2 Lighting Procedures
1. Broiler is
centered under
hood and
plugged in
2. Gas valve is
open when
handle is in line
(parallel to) the
pipe
3. Turn ventilation
system on
PILOTS MUST BE LIT WITHIN 5 MINUTES; IF YOU EXCEED 5
MINUTES, PRESS THE RESET BUTTON NEXT TO THE ON/OFF
SWITCH AND REPEAT IGNITION PROCEDURES. IF REIGNI-
TION FAILS, COMPLETELY SHUT OFF THE BROILER, WAIT 5
MINUTES AND REPEAT THE IGNITION PROCEDURES.
Reset Button
1
Turn the MAIN POWER SWITCH (a) on. Starting
with the MAIN CHAMBER RED PILOT BUTTONS,
press and hold the
LOWER BUTTON FIRST (b) for
30 seconds after the pilot has lit. Then press the
UPPER PILOT BUTTON (c) for 30 seconds after
the pilot has lit.
2
After releasing red pilot buttons; check GAS PRES-
SURE GAUGE (a) reading. Gauge should read 4.If
not, follow troubleshooting tips in section E of this
manual. Verify that main chamber burners - upper
and lower - have lit.
3
Move to the FLEX CHAMBER RED PILOT
BUTTON (a), push and hold for 30 seconds after
the pilot has lit. Release, and verify that the burners
have lit, and that the
GAS PRESSURE GAUGE (b)
reads 4.
a
WARNING
THE VENTILATION SYSTEM MUST
BE ON AT ALL TIMES DURING
BROILER OPERATION. OPERATING
BROILER WITHOUT PROPER
VENTILATION IS A SEVERE FIRE
HAZARD.
MAIN CHAMBER IGNITION
b
c
PRE-LIGHTING PREPARATION
FLEX CHAMBER IGNITION
a
a
b
Nieco Corporation - Model 9025