Broil King 9025 Oven User Manual


 
7
Nieco Corporation - Model 9025
*
12(305mm) Minimum, preferably 610 mm (24) or more for service. Location clearances are from walls of broiler height.
B.4 Hood Requirements
This appliance must be installed under a ventilation hood of adequate size and the following minimum
capacity:
Model SCFM
9025 1000
Do not obstruct the flow of combustion and ventilation air. An adequate air supply must be available for
safe and proper operation.
B.5 Clearance
For proper installation the minimum clearance from combustible and non-combustible construction must
be 305 mm (12) from the back and 305 mm (12) from the front of the machine. Keep appliance area
free from combustibles.
To facilitate disassembly and service of the unit a minimum of 610 mm (24) should be allowed on the
control panel (feed end) of the broiler, as well as in front and back of the broiler.