Page 10
TROUBLESHOOTING (cont.)
Problem
No hot water dispensed from faucet
(SLF only)
Probable Cause
1. Hot Water Switch
2. Hot Water Dispense Valve
3. Inlet Solenoid Valve (Faucet)
Remedy
Refer to Service - Hot Water Switch
for testing procedures. See page 24.
Refer to Service - Hot Water Dis-
pense Valve for testing procedures.
See page 19.
Refer to Service - Inlet Solenoid
Valve (faucet) for testing proce-
dures. See page 20.
Beverage overflows decanter.
Weak beverage.
1. Beverage left in decanter
1. Type of paper filters
2. Coffee
3. Sprayhead
4. Funnel loading
5. Water temperature
The brew cycle should be started
only with an empty decanter under
the funnel.
BUNN® paper filters should be used
for proper extraction.
A sufficient quantity of fine or drip
grind coffee should be used for
proper extraction.
B.O.M. sprayhead #01082.0000
should be used to properly wet the
bed of ground coffee in the funnel.
The BUNN® paper filter should be
centered in the funnel and the bed
of coffee leveled by gentle shaking.
Place a funnel over an empty de-
canter on the warmer beneath the
sprayhead. Place the On/Lower
brew station warmer switch in the
upper position, press the start
switch, and check the water tem-
perature immediately below the
sprayhead with an accurate ther-
mometer. The reading should not
be less than 195° F. Adjust the con-
trol thermostat slightly clockwise to
increase the water temperature.
(Added November 1999)