Bunn S L &S L F Coffeemaker User Manual


 
Page 26
BLK
SW4
WHI/VIO
WHI/VIO WHI
WHI
OPTIONAL HOT WATER FAUCET SYSTEM
120 VOLTS AC 2 WIRE
120/240 VOLTS AC 3 WIRE
SINGLE PHASE
10305.0000M 11/99 © 1989 BUNN-O-MATIC CORPORATION
WHIBLK
AUXILIARY OUTLET
WHI/RED
BLK
"KEEP WARM" HEATER
WHI
BLK
GREEN
WHI
SCHEMATIC WIRING DIAGRAM SL
TANK HEATER
L1
PROTECTION SW
LEVEL SW
VIO
BREW STATION WARMER
RED
SW3
WHI
BLK
K-5 K-7
WHI
WHI
BLK
SW 2
RED RED
RED
BRN/BLK
A
B
WHI/RED
WHI
WHI/RED
RED (MODEL 35)
N L2
WHI (MODELS 15 & 20)
BLU/BLK
TOP WARMER
WHI
WHI
BLK
SW 1
WHI/VIO
BLK
WHI
VIO
BR. RECT
OPTIONAL LOW WATER PRESSURE VALVE
WHI
OPTIONAL FLASHING INDICATOR
BLK
4
3
2
1
PNK
GRY
L.E.D.
INDICATOR
TIMER
(200 WATT
MAXIMUM)
SOL
SOL
1
SOL
2
SOL
3
SW. & THERMOSTAT
LIMIT
THERMOSTAT
OVERFLOW
BLU/BLK
K
W
H
I
/
R
E
D
B
L
K