Bunn S L &S L F Coffeemaker User Manual


 
Page 4
ELECTRICAL REQUIREMENTS
CAUTION - Do not connect the brewer to the power source until specified in Initial Set-Up.
MODEL 15 has an attached cordset, and requires 2-wire
grounded service rated 120 volts ac, 15 amp, single phase, 60
Hz.
MODEL 20 requires 2-wire, grounded service rated 120 volts
ac, 20 amp, single phase, 60 Hz. Proceed as follows:
MODEL35 requires 3-wire,
grounded service rated 120/208
or 120/240 volts ac, 20 amp,
single phase, 60 Hz. Proceed as
follows:
Electrical Hook-Up
CAUTION – Improper electrical installation will damage electronic components.
1. An electrician must provide electrical service as specified.
2. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
3. Remove the front panel beneath the sprayhead and rotate the control thermostat knob fully counterclockwise
to the “OFF” position.
4. Remove the rear panel, feed the cord through the strain relief at the rear of the brewer, and connect it to the
terminal block. Replace the rear panel.
5. Connect the brewer to the power source and verify the voltage at the terminal block before proceeding.
Replace the front panel.
6. If plumbing is to be hooked up later, make sure that the brewer is disconnected from the power source. If
plumbing has been hooked up, the brewer is ready for Initial Set-Up.
USER NOTICES (cont.)
This equipment is to be installed to
comply with the Basic Plumbing Code of
the Building Officials and Code
Administrators International, Inc. (BOCA)
and the Food Service Sanitation Manual
of the Food and Drug Administration (FDA).
00656.0000
WARNING
HOT
WATER
12744.0000
120V.A.C.
NEUTRAL
WHITE
L1 BLACK
208 or 240
Volts A.C.
L2 RED
WHITE
NEUTRAL
L1 BLACK
120 V.A.C.
120 V.A.C.
(Revised November 1999)