Bunn WDG-2 Coffee Grinder User Manual


 
11
Problem
Grinder will not start.
Remedy
(A) Plug-in the grinder.
(B) Check the voltage at the wall
outlet with a voltmeter. It must
be 120 volts ac.
(A) Momentarily press the Off/On/Start
switch to the “START” (lower) position.
(B) Refer to
Service
- Off/On/Start
switch for testing procedures. See page
13.
Refer to
Service
- Timer for testing pro-
cedures. See page 16.
Refer to
Service
- Weight Control Board
for testing procedures. See page 18.
Remove Grinder rear cover. Press the
red “Reset” button, one located on rear
of each motor. Listen carefully for a
“click”. This resets the motor protec-
tion circuit and indicates that an over-
load may have been encountered by the
motor. (An overload can occur when
something other than coffee is inserted
into the hopper for grinding.) Refer to
Service -
Motors for disassembly pro-
cedures. See page 14.
Probable Cause
1. No power or incorrect voltage
2. Off/On/Start switch
3. (A) Timer - DG-2
(B) Weigh Control Board WDG-2
4. Motor overload protector
TROUBLESHOOTING
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems
encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.
Inspection, testing, and repair of electrical equipment should be performed only by qualified
service personnel.
All electronic components have 120 volt ac and low voltage dc potential on their terminals.
Shorting of terminals or the application of external voltages may result in board failure.
Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be
permanent. If an intermittent condition is encountered, the cause will likely be a switch contact
or a loose connection at a terminal or crimp.
Make certain that all electrical connections are tight and isolated.
WARNING
Exercise extreme caution when servicing electrical equipment.
Turn power OFF when servicing, except when electrical tests are specified.
Follow recommended service procedures.
Replace all protective shields or safety notices.
10854 030300