ELECTRICAL REQUIREMENTS
This grinder has an attached cordset and requires 2-wire, grounded service rated 120 volts ac, 15 amp,
single phase, 60 Hz.
OPERATING CONTROLS
Off/On/Start Switch
OFF - (upper position) Switching to this position stops all operation of the grinder.
ON - (middle position) The switch will return to this position after a grind cycle has begun and
will remain in this position after grinding has ceased.
START - (lower, momentary position) Pressing the switch to this position and releasing initiates
a grind cycle.
Hopper Selector Switch
LEFT - Switching to this position allows beans to be ground from the left
hopper.
RIGHT - Switching to this position allows beans to be ground from the
right hopper.
Dispense Timer - DG-2
The dispense timer controls the amount of beans that will be ground in a cycle. The timer can be adjusted
to dispense a different amount from each hopper. The scale is from 0.1 to 60.0 seconds. Refer to the
Adjustments section for timer setting chart. See page 7.
+/Increase - (left momentary push-button)
Pressing this button will increase the dispense interval on the timer while
the readout is displayed. The interval will change slowly for the first second’s
indication, then speed-up for the next fifteen second’s indication, and increase
very fast after that until it reaches the limit on the scale.
DISPLAY - (center momentary push-button)
Pressing this button will display the current timer readout. The timer can
only be adjusted while the readout is displayed. The indication on the display
will last for five minutes.
–/Decrease - (right momentary push-button)
Pressing this button will decrease the dispense interval on the timer while
the readout is displayed. The interval will change slowly for the first second’s
indication, then speed-up for the next fifteen second’s indication, and increase very fast after that until it reaches
the limit on the scale.
DISPENSE TIME (Seconds)
DISPLAY
Increase Decrease
Readout will be displayed for 5 minutes.
Timer can only be adjusted
while readout is displayed.
+
WARNING
HAZARDOUS VOLTAGE
UNPLUG GRINDER
BEFORE REMOVING!
I 0.0