Set up the CO2 tank:
NOTE
A full CO2 tank can be dangerous if it is dropped or mishandled. Handle with care
and keep the tank lid in place until the tank is properly secured in the
merchandiser.
a. Place the power switch in the OFF position.
b. Install a full CO2 tank on the merchandiser as shown. Secure the CO2
tank with the retaining chain. (Note the various retaining chain configura
-
tions.)
c. Remove the CO2 tank lid. Briefly open and close the CO2 cylinder valve
to blow out any foreign matter.
d. Locate the CO2 regulator and flat plastic washer (in a box), and the
tapered plastic washer (in plastic bag).
e. Connect the CO2 hose from the secondary regulator tee fitting to the reg-
ulator. Firmly tighten the fitting.
ADJUSTMENT
SCREW
CO CYLINDER
VALVE
2
ADJUSTMENT
LOCK NUT
CO HOSE
2
(REAR OF TANK SHOWN)
327p0008
CO CYLINDER
2
SYRUP TANKS
LOCATION 1
LOCATION 2
˜
CO CYLINDER
2
RETAINING
CHAIN
RETAINING
CHAIN
CO CYLINDER
2
LOCATION 1
RETAINING
CHAIN