Everpure 325 Water Dispenser User Manual


 
Cold Drink Center (327/328) Operator’s Guide
August, 2003 Page 14 3280020
a. Rotate the adjusting screw 1/8 turn:
CLOCKWISE to decrease water throw.
COUNTERCLOCKWISE to increase water throw.
b. Repeat the testing steps until the water throw is as desired.
6. Testing the syrup throw:
a. Place a graduated flask in the cup station.
b. Refer to "Set Up A Drink" on page 36, for information on how to set
your syrup and perform test throws.
c. Test throw syrup and compare the volume of syrup to the suggested vol-
ume in the table for the cup size being vended.
d. If necessary, adjust the syrup valve to obtain the proper volume.
e. Repeat steps c and d for all selections.
NOTE
Software times do not control the output volume of diaphragm
pumps; they simply start the motor. The output volume is
controlled with a mechanical adjustment in the pump.
LIMIT SCREW
(
SEE WARNING)
ADJUSTING SCREW