Everpure 325 Water Dispenser User Manual


 
Cold Drink Center (327/328) Operator’s Guide
August, 2003 Page 10 3280020
NOTE
Not using a wrench on the tank side may damage the CO2 tank,
resulting in personal injury.
f. Using two wrenches, tighten the line to the regulator.
g. Insert the flat washer into the regulator nut.
h. Using two wrenches, connect the regulator to the tank outlet and tighten
in place.
i. Open CO2 tank valve.
j. Adjust the CO2 regulator so that the gauge reads 60 PSI (4.10 bar).
k. The secondary regulator is located behind the monetary panel on the
right side of the cabinet. Adjust the secondary regulator to 40 PSI (2.76
bar).
l. Lock the adjustment screw in place.
m. Remove the water bath cover and actuate the pressure relief valve
located on top of the carbonator tank for 3 to 5 seconds.
n. Check for gas leaks along the CO2 line.