CE and Non-CE Gas Conversion Instructions
1. Between G20- and G25-type Natural Gas, adjust the gas pressure at the regulator. (Refer to the
CE Standard Burner Manifold Gas Pressure Chart.) Do not change the orifice.
2. Between a 2
nd
family gas (G20 or G25) and a 3
rd
family gas (G31 Propane):
a. Change the orifices.
b. Change the pilot.
c. Change the gas valve regulator.
d. Adjust the manifold pressure.
3. Remove the rating plate and install a new one. Call your local service agency or KES for a new
rating plate.
4. If the destination language changes, replace the labels. Call your local service agency or KES
for a label kit. The language of reference will be on the corner of the label.