Frymaster BIELA14 Fryer User Manual


 
1-33
Problem Probable Causes Corrective Action
M3000 display shows
IS VAT FULL?
YES NO.
A filter error has occurred due to dirty or
clogged filter pad or paper, clogged filter
pump, filter pump thermal overload,
improperly installed filter pan components,
worn or missing O-rings, cold oil or an
actuator problem.
Follow the steps in the flowchart in section
1.14.5.
Fryer filters after each
cook cycle.
Filter after setting incorrect or software
update issue.
Overwrite the filter after setting by re-entering
the filter after value in level two. Ensure that
the down arrow is pressed after entering the
value to save the setting (see section 4.13.5 on
page 4-33 in the BIELA14 IO Manual).
1.14.2 M3000 Useful Codes
To enter any of the following codes: Press and hold 3and 4simultaneously for TEN seconds; three chirps
sound. The computer displays TECH MODE. Enter the codes below to perform the function.
1658 Change from F° to C° The computer displays off. Turn the computer on and check
temperature to see the temperature scale. If the desired scale is not displayed, repeat.
3322 Reset Factory Menu The computer displays COMPLETE and then off. (NOTE:
This will delete any hand-entered menu items).
1650 – Enter Tech Mode. See page 1-36 to reset passwords and change filter pad time.
1212 Switch between Domestic Menu and International Menu. The computer displays
COMPLETE and then off. (NOTE: This will delete any hand-entered menu items).
0469 Reset FILTER STAT DATA
The following codes require the removal and reinsertion of the J3 locator plug on the rear of the computer
before entering the code.
1000 Reset CALL TECH Message - Disconnect board locator plug (J3). Reinsert plug.
Enter 1000. Computer display switches to off. Remove and then restore power to the computer
using the 20-pin plug
.
9988 – Reset BADCRC Message - Disconnect board locator plug (J3). Reinsert plug. Enter
9988. Computer display switches to off. Remove and then restore power to the computer using
the 20-pin plug.
The following codes are entered when prompted to do so or from an energy misconfigured exception error.
1111 Reset SERVICE REQUIRED Message – Enter when the issue is fixed and prompted
to enter.
1234 Enter SETUP MODE from energy misconfigured exception error (This usually can be
done without pressing the filter buttons if an error is displayed.)
PASSWORDS
To enter level one, level two passwords: Press and hold the TEMP and INFO buttons simultaneously until
level 1 or level 2 is displayed. Release the buttons and ENTER Code appears.
1234 Fryer Setup, Level One and Level Two
4321 – Usage Password (resets usage statistics).