1.14.3 Service Required Errors
A SERVICE REQUIRED error alternating with YES displays on the computer. After YES is pressed the
alarm is silenced. The computer displays an error message from the list below three times with the
location of the error. Then the computer displays SYSTEM ERROR FIXED? YES/NO. If yes is chosen,
enter code 1111. If NO is chosen the system returns to cook mode for 15 minutes then redisplays error
until issue is fixed.
Pressing the MIB reset button during any filter function will generate a “SERVICE REQUIRED”
error.
This is a list of the service required errors and causes.
ERROR MESSAGE EXPLANATION
PUMP NOT FILLING Oil not returning to vat quickly. Possible
problems: dirty pad, bad or missing O-rings,
tripped or defective filter pump, actuators or
linkage.
DRAIN VALVE NOT OPEN Drain valve failed to open; the valve’s
position is unknown.
DRAIN VALVE NOT CLOSED Drain valve failed to close; the valve’s
position is unknown.
RETURN VALVE NOT OPEN Return valve failed to open; the valve’s
position is unknown.
RETURN VALVE NOT CLOSED Return valve failed to close; the valve’s
position is unknown.
MIB BOARD Problem with CAN communications; Check
for loose CAN connections between
computer and MIB board. MIB board failure
AIF BOARD MIB detects AIF missing; AIF board failure
ATO BOARD MIB detects ATO board connection lost;
ATO board failure
HIGH LIMIT FAILURE High limit circuit has an issue
AIF PROBE AIF RTD reading out of range
ATO PROBE ATO RTD reading out of range
TEMP PROBE FAILURE TEMP Probe reading out of range
MIB SOFTWARE Internal MIB software error
INVALID CODE LOCATION SD card removed during update
MISCONFIGURED ENERGY TYPE Energy type in fryer setup is incorrect. (ie.
Set proper energy type gas or electric)
Press 1234 to enter setup to properly
configure fryer.
RTC INVALID DATE The date is invalid. Press 1234 to enter
setup to properly configure fryer and set
proper date.