Frymaster BIELA14 Fryer User Manual


 
1-35
1.14.4 Error Log Codes
Refer to page 1-39, level 2 program for access to the E-log. The ten most recent errors are listed from
A-J, with A being the most recent error.
Code ERROR MESSAGE
EXPLANATION
E01 REMOVE DISCARD (Right) A product cook is started on the right side of a split
vat or in a full vat that has a different setpoint other
than the current vat temperature.
E02 REMOVE DISCARD (Left) A product cook is started on the right side of a split
vat or in a full vat that has a different setpoint other
than the current vat temperature.
E03 ERROR TEMP PROBE FAILURE Temp probe reading out of range
E04 HI 2 BAD High limit reading is out of range.
E05 HOT HI 1
High limit temperature is past more than 410°F
(210°C), or in CE countries, 395°F (202°C)
E06 HEATING FAILURE A component has failed in the high limit circuit such
as computer, interface board, contactor or open-
high limit.
E07 ERROR MIB SOFTWARE Internal MIB software error
E08 ERROR ATO BOARD MIB detects ATO board connection lost; ATO
board failure
E09 ERROR PUMP NOT FILLING Oil not returning to vat quickly. Possible problems:
dirty pad, bad or missing O-rings, tripped or
defective filter pump, actuators or linkage.
E10 ERROR DRAIN VALVE NOT OPEN Drain valve failed to open; the valve’s position is
unknown.
E11 ERROR DRAIN VALVE NOT CLOSED Drain valve failed to close; the valve’s position is
unknown.
E12 ERROR RETURN VALVE NOT OPEN Return valve failed to open; the valve’s position is
unknown.
E13 ERROR RETURN VALVE NOT CLOSED Return valve failed to close; the valve’s position is
unknown.
E14 ERROR AIF BOARD MIB detects AIF missing; AIF board failure
E15 ERROR MIB BOARD Cooking computer detects MIB connections lost;
Check software version on each computer. If
versions are missing, check CAN connections
between each computer; MIB board failure
E16 ERROR AIF PROBE AIF RTD reading out of range
E17 ERROR ATO PROBE ATO RTD reading out of range
E18 Not currently used
E19 M3000 CAN TX FULL Connection between computers lost
E20 INVALID CODE LOCATION SD card removed during update
E21 FILTER PAD PROCEDURE ERROR
(Change Filter Pad)
25 hour timer has expired or dirty filter logic has
activated
E22 OIL IN PAN ERROR The MIB has reset the oil in pan flag.
E23 CLOGGED DRAIN (Gas) Vat did not empty during filtration
E24 AIF BOARD OIB FAILED (Gas) Oil is back sensor failed.
E25 RECOVERY FAULT Recovery time exceeded maximum time limit.
E26 RECOVERY FAULT CALL SERVICE Recovery time exceeded maximum time limit for
two or more cycles.
E27 LOW TEMP ALARM Oil temperature has dropped lower than 15°F (8°C)
in idle mode or 45°F (25°C) in cook mode.