Frymaster BIPH55 Fryer User Manual


 
4-4
DANGER
NEVER attempt to clear a clogged drain valve from the front of the valve! Hot oil will
rush out creating the potential for severe burns.
DO NOT hammer on the drain valve with the cleanout rod or other objects. Damage
to the ball inside will result in leaks and will void the Frymaster warranty.
2. After the oil has drained from the frypot,
rotate the filter handle to start the pump
and begin the filtering process. There
may be a slight delay before the pump
activates.
3. The filter pump draws the oil through the filter pad and circulates it back up to and through the
frypot during a 5-minute process called polishing. Polishing cleans the oil by trapping solid
particles in the filter pad.
4. After the oil is filtered (about 5 minutes), close the drain valve and allow the fryer to refill. Let
the filter pump run 15 to 30 seconds after the oil begins to bubble in the frypot then turn the filter
off but rotating the handle up.
WARNING
The filter pump is equipped with a manual reset switch in case the filter motor
overheats or an electrical fault occurs. If this switch trips, turn off power to the filter
system and allow the pump motor to cool 20 minutes before attempting to reset the
switch (see photo below).
Filter Pump Reset Switch
5. Ensure the drain valve is fully closed. (If the drain valve is not fully closed, the fryer will not
operate.) Turn the fryer ON and allow the oil to reach setpoint.
Rotate smaller
handle to
activate filter.