Frymaster BIPH55 Fryer User Manual


 
6-4
Problem Probable Causes Corrective Action
M2000 display
shows
LOW TEMP.
Frypot temperature is between 180°F
(82°C) and 315°F (157°C).
This display is normal when the
fryer is first turned on and may
appear for a short while if a large
batch of frozen product is added to
the frypot. If the display never
goes out, the fryer is not heating.
Shut the fryer down and call
FASC.
M2000 display
shows
PROBE
FAILURE.
Problem with the temperature
measuring circuitry including the
probe.
This indicates a problem within the
temperature measuring circuitry
that is beyond the scope of
operator troubleshooting. Shut the
fryer down and call FASC.
M2000 display
shows IGNITION
FAILURE.
Open drain valve, failed computer,
failed transformer, open high-limit
thermostat.
This indicates that the fryer is not
heating. It is displayed if the fryer
loses its ability to heat oil. It is
also displayed when the oil
temperature is above 450°F
(232°C) and the high-limit
thermostat has opened, halting the
heating of the oil. Verify that the
drain valves are fully closed. If
this does not correct the problem,
call your FASC.
M2000 display
shows HI-LIMIT.
Computer in hi-limit test mode.
This is displayed only during a test
of the hi-limit circuit and indicates
that the hi-limit has opened
properly.
Display shows
,
heating indicator
cycles on and off
normally, but
burners will not
light and blower is
not running.
Failed computer or damaged
computer wiring harness.
Call FASC.
Heat indicator off
upon initial startup.
Display shows
,
or with
alarm sounding.
Failed computer, damaged wiring
harness or connector
Call FASC