Frymaster BIPH55 Fryer User Manual


 
6-3
PROBLEM PROBABLE CAUSES CORRECTIVE ACTION
A. Dirty or obstructed combustion air
blower.
A. Clean and adjust per instructions
in Chapter 5 of this manual.
B. Dirty or obstructed gas valve vent
tube (non-CE fryers only).
B. Clean per instructions in Chapter
5 of this manual.
Fryer is operating
normally, but
produces a popping
sound when burners
ignite.
C. Malfunctioning combustion air
blower.
C. If blower is slow to come up to
speed, contact FASC for service.
Computer will not
go into program
mode or some
buttons do not
actuate.
Failed computer. Call FASC.
Heat indicator is on
and blower is
running, but burner
will not ignite.
Blown fuse on interface board or
ignition module.
Replace fuse.
6.3 Error Messages and Display Problems
Problem Probable Causes Corrective Action
M2000 display is in
wrong temperature
scale (Fahrenheit or
Celsius).
Incorrect display option programmed.
M2000 computers may be
programmed to display in either
Fahrenheit or Celsius. Refer to the
separate M2000 Computer
Operation Manual for instructions
on changing the display.
M2000 display
shows
HI.
Fryer is 15ºF (8ºC) above setpoint.
This display will appear only if the
fryer is in the non-dedicated mode
and the frypot temperature rises
15° (8°C) or more above the
programmed setpoint. This
indicates a problem with the
temperature control circuitry. Turn
the fryer off and call FASC.
M2000 display
shows
HOT.
Frypot temperature is more than
410ºF (210ºC) or, in CE countries,
395ºF (202ºC).
This in an indication of a
malfunction in the temperature
control circuitry, including a
failure of the high limit thermostat.
Shut the fryer down immediately
and call FASC.