Flue Information
A. Flue Components
B. Use of Elbows
These models are approved to use Simpson Dura-Vent or
Hearth & Home Technologies series pipes, components and
termination. Approved components are labeled for identi ca-
tion. This pipe is tested and listed as an approved compo-
nent of the stove.
DO NOT USE FIELD-FABRICATED FLUE COMPONENTS.
Refer to the flue manufacturer’s instructions.
This product is approved to be flued either horizontally,
through the side wall or vertically through the roof. You may
flue through a Class A or masonry chimney if an approved
adapter is used.
This gas stove is a balanced ue gas stove. All combus-
tion air must come directly from the outside of the building.
The ue pipe for this unit consists of an inner and an outer
pipe. The inner pipe carries the gas stove exhaust out of the
system, and the outer pipe brings fresh combustion air into
the gas stove.
Fire Hazard.
Explosion Risk.
Asphyxiation Risk.
Do NOT connect this gas gas stove to a chimney
ue serving a separate solid-fuel or gas burning
gas stove.
Flue this gas stove directly outside.
• Use separate ue system for this gas stove.
May impair safe operation of this gas stove or
other gas stoves connected to the ue.
WARNING
Diagonal runs have both vertical and horizontal flue aspects
when calculating the effects. Use the rise for the vertical
aspect and the run for the horizontal aspect. (See Figure
5.1.)
Two 45° elbows may be used in place of one 90° elbow. On
45° runs, one foot of diagonal is equal to 21.6 cm horizon-
tal run and 21.6 cm vertical run. A length of straight pipe is
allowed between two elbows. (See Figure 5.1.)
Vertical
Horizontal
30.5 cm
21.6 cm
21.6 cm
Vertical and horizontal measurements were made using the
following standards.
C. Measuring Standards
CAUTION
ALL ue con guration speci cations MUST be followed.
This product is tested and listed to these
speci cations.
Appliance performance will suffer if speci cations are
not followed.
Figure 5.1
Pipe measurements are from center line to center line.
Horizontal terminations are measured to the outside of
the mounting surface ( ange of termination cap). See
Figure 4.1 on page 8.
Horizontal pipe should be installed level with no rise.
A round support box/wall thimble or heat shield is
required when the ueing passes through a combus-
tible wall.
A support box or ceiling restop is required when the
ueing passes through a combustible ceiling.
Roof ashing and a storm collar are required when ue-
ing passes through the roof.
Follow instructions provided with the ueing for installa-
tion of these items.