Example: Transfer
Switch Using Two
3-Port Switches
This example shows how to configure the HP E1368A Microwave Switch
to either route a signal directly to the output, or route it through an external
device before being output. For the example, two switches (channels 00
and 01) will be used. Figure 3-5 shows how to connect channels 00 and 01.
To route the signal directly, execute:
OPEN (@100,101) Connects port C to port 1 of both
channels and routes the signal
directly to the output.
To route the signal through the external device, execute:
CLOS (@100,101) Connects port C to port 2 of both
channels and routes the signal
through the external device to the
output.
Figure 3-5. Example: Transfer Switch (two channel)
36 Using the HP E1368A/69A/70A Modules Chapter 3