HP (Hewlett-Packard) E1368A Microwave Oven User Manual


 
:COUNt? ARM:COUNt? [MIN | MAX] returns the current number of scanning cycles
set by
ARM:COUNt. The current number of scans cycles is returned when
no
MIN or MAX parameter is sent. With MIN or MAX passed as parameters,
MIN returns 1 and MAX returns 32767.
Parameters
Parameter Name Parameter Type Range of Values Value
MIN | MAX numeric MIN = 1, MAX = 32767 cycles
Comments Related Commands: INITiate:IMMediate
Example Query Number of Scanning Cycles
This example sets a Microwave Switch for 10 scanning cycles of channels
00 through 02, and queries the number of scan cycles set. The
ARM:COUN? command returns 10.
ARM:COUN 10 Set 10 scans per INIT command.
ARM COUN? Query number of scanning cycles.
52 HP E1368A/69A/70A Command Reference Chapter 4