Hobart HL200 Mixer User Manual


 
Remove and Clean Bowl Guard Wire Cage (Fig. 11)
1. Rotate wire cage to your left until the three carriers align with the carrier escape slots in
the circular ridge of the planetary drip cup.
2. Lift the wire cage straight up so the carriers escape from the slots on the drip cup. The
bowl guard wire cage can now be removed by pulling toward you.
Escape Slots
(3)
Fig. 11
3. Wash the bowl guard wire cage in a sink, rinse with clear water, and dry with a clean
cloth.
4. The splash guard can be wiped off and/or washed with a cloth or sponge using warm,
soapy water. Rinse with clear water and dry with a clean cloth.
Reinstall Bowl Guard Wire Cage
1. Position the ring of the bowl guard wire cage so the carriers are positioned above the slots
in the planetary drip cup.
2. Lower the bowl guard wire cage so the carriers pass through the slots.
3. Rotate the bowl guard wire cage to your right until it contacts the stop, closed position.
15