U
V
L1
L2
L1/L
1MTR
AC
INDUCTION
MOTOR
13
12
T1-BLUE
T3-ORANGE
FWD
PLC
MIXER RUN
24 VDC
GND
DISPLAY
30C
30B
1K
0
1
1CR
TIMER
READY
OUTPUT
1LS
BOWL
GUARD
SWITCH
L2/N
GROUND
8
4
6
2
CONTACT-NORMALLY OPEN (N.O.)
CONTACT-NORMALLY CLOSED (N.C.)
GND GROUND
PB PUSH BUTTON-STOP (N.C.)
PB PUSH BUTTON-START (N.O.)
INSEPARABLE CONNECTION
SEPARABLE CONNECTION
HEAVY LINE DENOTES EXTERNAL WIRING
DASHED LINE DENOTES BOUNDARY
OF PRINTED WIRING BOARD
MOTOR
LS LIMIT SWITCH - N.O.
CR CONTROL RELAY COIL
LIGHT LINE DENOTES FIXED PREWIRING
(PRINTED CIRCUIT WIRING OR OTHER).
SYMBOL DEFINITIONS
100-120/50/60/1
200-230/50/60/1
1CR
DERIVED FROM F34936A
TIME
TIME
ADJUSTMENT
SPEED
SELECTOR
A
11
SWITCH STATE TABLE
SWITCH
CONDITION
RESULT
BOWL
SWITCH
BOWL
GUARD
OPEN
CLOSED
OPEN
CLOSED
CAGE IN MIX POSTION
CAGE OPEN
BOWL IN MIX POSTION
BOWL OUT MIX POSTION
G
MIXER
DRIVE
X1
X2
CM¹
X3
RS485
1K
RS485
Y1
Y1E
BUZZER
1K
C
CN1-16
CN1-14
CN1-11
CN1-12
CN1-5
CN1-7
CN1-6
CN1-8
CN1-9
CN1-10
CN1-13
CN3-1
CN1-15
CN1-4
CN1-1
CN2-1
CN2-6
2
4
10
9
w
T2-BROWN
CN3-2
CM²
2LS
BOWL
SWITCH
1MTR
2K
STD
4PB
2K
RECIPE 3PB
2K
RECIPE PROGRAM KEYS
PGM
SPEED
SELECT
SAVE
TIME
SYMBOLS AND LABELS IN ITALICS
USED ON RECIPE TIMER ONLY
STD
4PB
CN4
-1
CN4
-2
CN4
-3
STOP 2PB
START 1PB
1
2
3
4
CN5-3 CN5-2
CN5-1
ELECTRICAL AND GROUNDING CONNECTIONS
MUST COMPLY WITH THE APPLICABLE
PORTIONS OF THE NATIONAL ELECTRICAL
CODE AND/OR OTHER LOCAL ELECTRICAL CODES.
WARNING
HL200 MIXER
ELECTRICAL DIAGRAM