Cornelius Universal C-750 Beverage Dispenser User Manual


 
27 185211000
Trouble RemedyProbable Cause
CONDENSER FAN MOTOR
NOT OPERATING. (CONTD)
C. Inoperative condenser fan
motor.
C. Replace condenser fan motor.
NOTE: If overload protector cuts out compressor, condenser fan motor will continue to operate;
otherwise troubleshooting condenser fan motor problems is same as for ‘‘COMPRESSOR DOES NOT
OPERATE’’ paragraph plus the following:
AGITATOR MOTOR NOT
OPERATING.
A. Unit power cord or agitator
motor power cord
disconnected or Unit power
switch (115 VAC Unit only) in
‘‘OFF’’ position.
A. Plug in power cords or place Unit
power switch in ‘‘ON’’ position.
B. No power source (blown fuse
or tripped circuit breaker).
B. Replace fuse or reset circuit
breaker. (Note: Fuse or circuit
breaker are not part of Unit.)
C. Agitator motor propeller
obstructed.
C. Remove obstruction.
D. Low voltage. D. Voltage must be at least 103 volts
(115 VAC Unit) or 208 volts (230
VAC Unit) at compressor
terminals when compressor is
trying to start.
E. Loose, disconnected, or
broken wiring.
E. Tighten connections or replace
broken wiring.
F. Inoperative agitator motor. F. Replace agitator motor.