KitchenAid KHMS105E Microwave Oven User Manual


 
2-18
FAN COVER
COVER
SCREW
FOLD
BACK
FLAT
WASHER
HEX
NUT
BLUE WIRE
BROWN WIRE
TEMPERATURE
PROBE SOCKET
REMOVING THE TEMPERATURE PROBE SOCKET
4. From the top and back of the control
panel,
lift the top locking tab and pull
the top of the panel out slightly, then lift
the bottom tabs of the panel out of the
slots and pull it forward. Set the panel
inside the oven cavity while you work.
5. Remove the center screw from the fan
cover and fold the cover back (unhook the
three tabs) so you can access the tem-
perature probe socket.
6 Remove the hex nut and flat washer from
the temperature probe socket, and re-
move the socket from its mounting hole in
the oven.
7. Unsolder the two wires from the tempera-
ture probe socket.
8. Mount the new temperature probe socket
and reassemble the microwave oven.
WARNING
Personal Injury Hazard
Disconnect from the electrical supply be-
fore servicing the unit. Failure to do so
could result in death or electrical shock.
1. Disconnect the electrical supply to the
microwave oven.
2. Remove the two screws from the top of
the cabinet for the vent grille and remove
the grille (see the illustration on page
2-3).
3. Remove the screw from the top center tab
of the control panel (see the illustration
on page 2-17).