125
ENGLISH
- page 1
ESPAÑOL
- página 7
1
Instructions for Service Kits 42810-0120, 42810-0125, 42810-0126, 42810-0127, 43061, 44664
Gas Conversion Kit for Middleby Marshall Ovens
Propane to Natural Gas Operation
KIT COMPONENTS:
Qty. PS200 PS220/224 PS310/360 PS360WB PS360WB70/EWB PS555 PS570S Description
1 42810-0125 42810-0126 42810-0120 42810-0127 44664 43061 42810-0127 KIT, GAS CONVERSION, PROPANE
TO NATURAL
1 22176-0010 22176-0016 22176-0004 22176-0014 22176-0014 43059 22176-0014 ORIFICE, MAIN
0.204/5.18mm 0.182/4.62mm 0.219/5.56mm 0.250/6.35mm 0.250/6.35mm 0.228/5.79mm 0.250/6.35mm
1 < - - - - - - - - - - - - - - - - - - - - - - - - 22174-0011 - - - - - - - - - - - - - - - - - - - - - - - - > ORIFICE, PILOT
0.028/0.71mm
1 22174-0006 22174-0006 22174-0006 22174-0006 22174-0006 * NONE * 22174-0006 * ORIFICE, BYPASS (HIGH-FLAME)
0.060/1.52mm/ 0.060/1.52mm/ 0.060/1.52mm/ 0.060/1.52mm/ 0.060/1.52mm/ 0.060/1.52mm/
#53 drill #53 drill #53 drill #53 drill #53 drill #53 drill
1 < - - - - - - - - - - - - - - - - - - - - - - - - 28092-0019 - - - - - - - - - - - - - - - - - - - - - - - - > KIT, GAS CONTROL VALVE SPRING
- NATURAL GAS
1 < - - - - - - - - - - - - - - - - - - - - - - - - 22500-0064 - - - - - - - - - - - - - - - - - - - - - - - - > LABEL, NATURAL GAS (YELLOW/
GREEN)
1 < - - - - - - - - - - - - - - - - - - - - - - - - 22500-0123 - - - - - - - - - - - - - - - - - - - - - - - - > LABEL, GAS CONVERSION
1 < - - - - - - - - - - - - - - - - - - - - - - - - 22501-0007 - - - - - - - - - - - - - - - - - - - - - - - - > TAG, GAS CONTROL CONVERSION
1 < - - - - - - - - - - - - - - - - - - - - - - - - 88210-0070 - - - - - - - - - - - - - - - - - - - - - - - - > INSTRUCTIONS
NOTE: The bypass orifice is not used if the oven is equipped with a modulating gas valve. These ovens include:
PS360EWB (all)
PS555 (all)
PS570S (units produced 4/00 or later)
For additional information, refer to Part III of these instructions (Bypass Orifice Conversion).
WARNING
THIS CONVERSION KIT IS TO BE INSTALLED BY A MIDDLEBY MARSHALL AUTHORIZED SERVICE AGENT
IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS AND ALL CODES AND REQUIREMENTS
OF THE AUTHORITY HAVING JURISDICTION. FAILURE TO FOLLOW INSTRUCTIONS COULD RESULT IN
SERIOUS INJURY OR PROPERTY DAMAGE. THE AUTHORIZED SERVICE AGENT PERFORMING THIS
WORK ASSUMES RESPONSIBILITY FOR THIS CONVERSION.
Middleby Cooking Systems Group 1400 Toastmaster Drive Elgin, IL 60120 USA (847) 741-3300 FAX (847) 741-4406
*
P/N 88210-0070 Rev. C V1 8/00
WARNING
BEFORE PERFORMING ANY SERVICE WORK, THE ELECTRICAL POWER SUPPLY
AND THE GAS SUP-
PLY
MUST BE TURNED OFF.
IMPORTANT
THIS CONVERSION KIT IS INTENDED FOR AGA-, CGA-, AND CSA-APPROVED MIDDLEBY
MARSHALL GAS-FIRED OVENS OPERATING AT ALTITUDES UP TO 5000 FT. (1524m).
FOR OVENS INSTALLED AT ALTITUDES ABOVE 5000 FT. (1524m), CONSULT THE FAC-
TORY BEFORE INSTALLING THIS KIT.
THIS KIT MAY NOT BE USED WITH CE-APPROVED MIDDLEBY MARSHALL OVENS.
FOR THESE OVENS, FOLLOW THE GAS CONVERSION INSTRUCTIONS IN THE INSTAL-
LATION SECTION OF THE OVENS OWNERS OPERATING AND INSTALLATION MANUAL.
SECTION 3 - SERVICING COMPONENTS
Appendix - Instructions for All Gas Conversion Kits
for Ovens with Wayne Burner, Propane to Natural Gas, 8/00