138
Figure 7
Yellow “NAT.” label placement
(on burner housing)
Figure 8
Conversion information label
THIS APPLIANCE HAS BEEN CONVERTED ON _______________ TO ______________ GAS WITH KIT
NO. ________________ BY _______________ , WHO ACCEPTS THE RESPONSIBILITY FOR
THE CORRECTNESS OF THIS CONVERSION.
MODEL NO. MAIN BURNER ORIFICE SIZE MANIFOLD PRESSURE
INPUT RATING MAXIMUM INLET PRESSURES
Date of conversion
NATURAL
36863
Stated on the
oven’s data plate
175,000 BTU
Signature of technician
performing conversion
.234”/5.94mm
14” W.C./34.9mbar
Measured value
recorded in Step 8.3
Figure 9
Conversion information label placement
Page 4 of 4 P. Jan. 98 Rev B p/n 36862
THIS APPLIANCE HAS BEEN CONVERTED ON _______________ TO ______________ GAS WITH KIT
NO. ________________ BY _______________ , WHO ACCEPTS THE RESPONSIBILITY FOR
THE CORRECTNESS OF THIS CONVERSION.
MODEL NO. MAIN BURNER ORIFICE SIZE MANIFOLD PRESSURE
INPUT RATING MAXIMUM INLET PRESSURES
THIS APPLIANCE HAS BEEN CONVERTED ON _______________ TO ______________ GAS WITH KIT
NO. ________________ BY _______________ , WHO ACCEPTS THE RESPONSIBILITY FOR
THE CORRECTNESS OF THIS CONVERSION.
MODEL NO. MAIN BURNER ORIFICE SIZE MANIFOLD PRESSURE
INPUT RATING MAXIMUM INLET PRESSURES
PS360EWB placement
PS360WB70 placement
Upper oven
label location
Lower oven
label location
9. CONVERSION LABELING
9.1 Remove and discard the round, red “LPG.” label from the front
face of the burner plenum.
9.2 Apply the round, green “NAT.” label (p/n 22500-0064) to the
front face of the burner housing as shown in Figure 7.
9.3 Close the machinery compartment access door.
9.4 Record the information requested on the silver conversion
information label. Figure 8 shows a representation of this label.
9.5 Apply the conversion information label to the front of the
machinery compartment access door, next to the control panel.
See Figure 9.
SECTION 3 - SERVICING COMPONENTS
Appendix - Instructions for Service Kit 36863 - Gas Conversion Kit for
PS360EWB/WB70 with Midco Burner, Propane to Natural Gas, 1/98