MTD -ERV 365 Ventilation Hood User Manual


 
Menu P1 ! Status of the functions
Ventilation functions
Sub-menu Description Activated / not activated
P10 Menu 20 currently active? Yes (1) / No (0)
P11 Menu 21 currently active? Yes (1) / No (0)
P12 Menu 22 currently active? Yes (1) / No (0)
P13 Menu 23 currently active? Yes (1) / No (0)
P14 [Not available] [Not available]
P15 Menu 25 currently active? Yes (1) / No (0)
P16 Menu 26 currently active? Yes (1) / No (0)
P17 Menu 27 currently active? Yes (1) / No (0)
P18 Menu 28 currently active? Yes (1) / No (0)
P19 Menu 29 currently active? Yes (1) / No (0)
2
Instructions for the User 11
Menu P2 ! Set time delays
Time delay values
muminiMnoitpircseDunem-buS Maximum Default
setting
P20
(Option)*
Deactivation delay for extractor hood
function.
'x' minutes after pressing the extrac-
tor hood switch, the MTD-ERV 350
returns to the previously set level.
0 Min. 180 Min. 30 Min.
P21
(Option)*
Note:
Only for systems with wired
switch and only if your system is
equipped with a second position
switch in the bathroom.
Activation delay for the bathroom
switch (to switch to the HIGHEST LEVEL).
'x' minutes after turning on the
bathroom switch, the MTD-ERV 350
switches to the HIGHEST LEVEL.
0 Min. 15 Min. 0 Min.
P22
(Option)*
Note:
Only for systems with wired
switch and only if
your system is equipped with
a second position switch in the
bathroom.
Deactivation delay for the
bathroom switch (to switch to the NOR-
MAL LEVEL).
'x' minutes after turning on the bath-
room switch, the MTD-ERV 350 re-
turns to the NORMAL LEVEL.
0 Min. 120 Min. 30 Min.
P23
Note:
Only for systems with a wired
position switch.
Deactivation delay
for ventilation position 3.
When position 3 (HIGHEST LEVEL) is
switched on briefl y (< 3 seconds), the
MTD-ERV 350 remains at this position
for the time set in this menu.
If, within the run-down time, the posi-
tion switch or the radio remote control
is activated, the MTD-ERV 350 switches
immediately to the set ventilation level.
0 Min. 120 Min. 30 Min.
P24 Filter warning
Here the user can select when "FILTER
DIRTY" is to appear on the CC Ease
display.
1 week 26 weeks 16 weeks