Sanyo CHDX07263 Refrigerator User Manual


 
2
2 - 34
10. Compressor
W-2WAY ECO-i SYSTEM
Outdoor Unit Repair Procedures
(1)
(1)
(C) Replacing multiple compressors
Removal
Follow the instructions in “(A) Replacing the inverter compressor,” “(B) Replacing constant-speed compressor,”
and remove the compressors.
* There is no predetermined sequence for removal; any compressor may be removed first.
Installation
Follow the instructions in “(A) Replacing the inverter compressor,” “(B) Replacing constant-speed compressor,”
and install the compressors.
* There is no predetermined sequence for installation; any compressor may be installed first.