Turbo Chef Technologies C3/C Convection Oven User Manual


 
Theory of Operation
4-3
Fault Code Messages Matrix
Old Error Code
New Error
Code
Warm-
Up
While
Cooking
Self-
Test
Reference
Chapter
BLOWER STATUS F3 BLOWER X
X
X 8
LOW COOK TMP F2 LOW TEMP
X
8
LOW MAG CURR F3 MAG CURR
X
X 9
DOOR MONITOR F4 MONITOR
X
7
MAG OVER TMP F5 MAG TEMP
X
X
X 9
ELEC OVR TMP F6 EC TEMP X X X 6
HX RISE LOW
Same
X X 8
THERMO OPEN
Same
X
X
X 8
OVEN DOOR AJAR Same X
X
X 7
EC TEMP HIGH F6 EC TEMP X X X 6
CLOSE OVEN
DOOR
same
X X X 7
TABLE 4-1
Notes:
1. All Fault Codes listed in BOLD will terminate a Cook Cycle upon discovery.
2. Any fault occurrence during Cook mode will be logged in the Fault Counter.
3. ELEC OVR TMP/EC TEMP HIGH/F6 fault code will not terminate a cook cycle,
however it will alert the user of a possible air circulation problem (Page 6-10)