CONNECTING A DRAIN PUMP
If a gravity drain connection is not available, and you have not
purchased the CLRCO2075 with factory installed pump, we strong-
ly recommend the use of the U-Line P60 drain pump. The U-Line
P60 drain pump is available through your Dealer, or direct from U-Line
with complete installation instructions. If a pump other than the U-Line
P60 drain pump is to be used, it must meet the following specifica-
tions:
• It must be UL listed and have a UL listed, 120 VAC, 3-wire
grounded power cord.
It must have overall maximum outside dimensions of 8-3/4" wide x
5-3/4" deep x 7-3/4" high.
• It must have a minimum flow rate of 15 gallons per hour at 10 feet
of lift.
It must have a sealed sump which does not allow water leakage in
the case of a power outage, restricted drain or pump failure.
It must have a check valve in the discharge line to prevent waste
water return to the pump.
• It must have an overflow protection control which will shut off power
to the ice maker in the event of a pump failure.
• It must have an operating temperature range of 50°F to 110°F
(10°C to 40°C).
In the event of a power outage, restricted drain or pump
failure, the failure to use the U-Line P60 drain pump or a
pump with the above listed specifications, could result in
substantial water leakage and pooling with severe and
costly water damage and related consequential damages
and harm.